LFS-10kv Indoor Epoxy Resin Current Transformer
The LFS-10 Current Transformer is an indoor cast resin product designed for AC power systems with a frequency of 50Hz and a rated voltage of up to 10kV. It features a fully enclosed epoxy resin structure, providing excellent insulation, moisture resistance, and durability. With high accuracy for current and energy measurement, along with superior thermal […]
The LFS-10 Current Transformer is an indoor cast resin product designed for AC power systems with a frequency of 50Hz and a rated voltage of up to 10kV. It features a fully enclosed epoxy resin structure, providing excellent insulation, moisture resistance, and durability. With high accuracy for current and energy measurement, along with superior thermal stability to withstand short-circuit impacts, the LFS-10 ensures reliable performance for metering and relay protection in modern power systems.
LFS-10 Current Transformer Type designation
The model designation reflects the key features of these current transformers:
- L: Indicates “Voltage Level” (kV).
- F: Denotes “Handcart Type.”
- S-10: Represents “TAP Complex.”
- Current Transformer: Identifies the device as a current transformer.
This clear designation ensures straightforward identification of the product’s structure and technical specifications.
LFS-10 Current Transforme Service conditon
- Altitude: ≤1000m
- Temperature: -5°C to +40°C
- Humidity: ≤80% at 20°C
- Environment: Free from harmful gases, chemicals, or pollutants that could damage insulation.
- Operational Stability: Designed for stable operation without chattering or impac
LFS-10 CT Technical Parameters
The LFS-10 Current Transformer is engineered for 10kV systems, accommodating primary currents from 5A to 1000A. It features multiple accuracy options (0.2S, 0.2, 0.5, 10P10, 10P15) and supports short-time thermal currents up to 63kA and dynamic currents up to 130kA, ensuring dependable performance for measurement and protection tasks.
Rated Primary
Current (A) |
Accuracy class
combination |
Rated Output (VA) | Rated Short-time
Current (kA/1s) |
Rated Dynamic
Current (kA) |
||||
---|---|---|---|---|---|---|---|---|
0.2S | 0.2 | 0.5 | 10P10 | 10P15 | ||||
5-100 | 0.2S/0.2S
0.210.2 0.2S/10P10 0.2/10P10 0.5/10P10 0.2/10P15 0.5/10P15 |
10 | 10 | 10 | 15
15 15 20 |
15 | 100|1n | 250|1n |
150 | 13.5 | 34 | ||||||
200 | 18 | 45 | ||||||
300 | 27 | 67.5 | ||||||
400 | 36 | 90 | ||||||
500 | 45 | 112.5 | ||||||
600 | ||||||||
750 | 20 | 63 | 130 | |||||
800~1000 |
Customization and Support: We offer flexible customization for the LFS-10 CT, including tailored current ratios, improved outputs, and solutions for unique environmental conditions. Contact us to craft a transformer tailored to your specific requirements.
Outline and Dimensions of Installation
- Troubleshooting Techniques for Burnt Voltage Transformers
- Error Analysis and Maintenance of Current Transformers in Power Systems
- Analysis and Troubleshooting of Common Issues with Current Transformers
- Causes and Solutions for False Fault Alarms in Zero-Sequence Current Transformers
- Zero-Sequence Current Transformers vs. Standard Current Transformer
- Fault Handling Considerations for Current and Voltage Transformers