JDZ10-3/6/10A RZL10 indoor epoxy cast-resin Voltage Transformer

160mm-wide line-to-line VT with 100V, dual-100V or 220V secondary options for 3–10kV panels

  • Single 100V output offers class 0.2/20VA through class 3/200VA configurations
  • Dual 100V secondaries provide isolated 10VA + 10VA measurement circuits
  • Class 3, 220V secondary at 80VA supports selected cabinet auxiliary-voltage loads
  • 3.6kV, 7.2kV and 12kV insulation versions match 3kV, 6kV and 10kV systems
  • Compact 330 × 160mm base and 300mm mounting spacing simplify switchgear integration

Overview

The JDZ10-3/6/10A/160 (RZL10) is an indoor single-phase epoxy cast-resin voltage transformer designed for 3kV, 6kV, and 10kV medium-voltage systems, corresponding to international voltage classes of 3.6kV, 7.2kV, and 12kV. It features solid epoxy insulation suitable for indoor air-insulated switchgear environments.

This line-voltage transformer provides standardized secondary outputs such as 0.1kV, dual 0.1kV, or 0.22kV for applications including metering, voltage monitoring, relay protection, and auxiliary power. It complies with GB20840.3-2013 and IEC61869-3:2011 standards and operates reliably at 50Hz or 60Hz within an ambient temperature range of -25°C to +40°C.

JDZ10 3610A RZL10 indoor epoxy cast resin Voltage Transformer 3

JDZ10-3/6/10A indoor cast-resin voltage transformer for medium-voltage switchgear

Key Ratings Snapshot

Parameter Rating
System Voltage 3kV / 6kV / 10kV
Voltage Class 3.6kV / 7.2kV / 12kV
Frequency 50Hz / 60Hz
Insulation Type Epoxy cast-resin
Primary Connection Line-to-line (phase-to-phase)
Secondary Outputs 0.1kV, 0.1/0.1kV, or 0.22kV
Max. Output Up to 400VA
Ambient Temperature -25°C to +40°C
Installation Indoor switchgear only
Standards GB20840.3-2013, IEC61869-3:2011
Weight Approx. 21.76kg
Structure Code RZL10-style, 160mm outline

Model Designation

Model Designation

  • J: Voltage transformer
  • D: Single-phase structure
  • Z: Epoxy cast-resin insulation
  • 10: Design series code
  • 3 / 6 / 10: Rated system voltage (3kV, 6kV, or 10kV)
  • A: Compact configuration
  • 160: RZL10-style outline size (160mm)

Construction

The JDZ10-3/6/10A/160 is constructed with a fully encapsulated epoxy cast-resin body, providing robust mechanical strength and excellent dielectric performance for indoor use. The primary and secondary windings are embedded within the solid resin matrix, ensuring moisture resistance, partial discharge suppression, and long-term stability under normal operating conditions. The compact 160mm RZL10-style housing minimizes cabinet footprint while maintaining required electrical clearances. All external terminals are securely integrated into the resin structure, and the unit includes provisions for grounding and secondary terminal access in compliance with safety and maintenance requirements.

Technical Parameters

Service Conditions

  • Ambient temperature: -5°C to +40°C
  • Altitude: up to 1000 m above sea level
  • Relative humidity: daily average not exceeding 95%, monthly average not exceeding 90%
  • Installation environment: indoor, non-corrosive, non-explosive, free from severe vibration and shock

Technical Parameters

The JDZ10-3.6/7.2/12kV (RZL10) indoor epoxy cast-resin voltage transformer is designed for metering, monitoring, and auxiliary power applications in medium-voltage switchgear. It features class 0.2 to 3.0 accuracy, rated outputs up to 200VA, and complies with IEC 61869 standards. The unit operates within -5°C to +40°C ambient temperature at altitudes up to 1000 m.

Model Variants

Type
(Ratio)
Rated
Voltage
(kV)
Accuracy Class
/ Rated
Output
Max.
Output
(VA)
Rated
Insulation
Level (kV)
JDZ10-3A/160 3 / 0.1 0.2 — 20VA
0.5 — 50VA
1.0 — 100VA
3.0 — 200VA
400 3.6/25/40
JDZ10-6A/160 6 / 0.1 0.2 — 20VA
0.5 — 50VA
1.0 — 100VA
3.0 — 200VA
400 7.2/30/60
JDZ10-10A/160 10 / 0.1 0.2 — 20VA
0.5 — 50VA
1.0 — 100VA
3.0 — 200VA
400 12/42/75
JDZ10-3A/160 3 / 0.1 / 0.1 0.2 / 0.2 — 10 / 10VA
0.2 / 0.5 — 10 / 10VA
350 3.6/25/40
JDZ10-6A/160 6 / 0.1 / 0.1 0.2 / 0.2 — 10 / 10VA
0.2 / 0.5 — 10 / 10VA
350 7.2/30/60
JDZ10-10A/160 10 / 0.1 / 0.1 0.2 / 0.2 — 10 / 10VA
0.2 / 0.5 — 10 / 10VA
350 12/42/75
JDZ10-3A/160 3 / 0.22 3.0 — 80VA 350 3.6/25/40
JDZ10-6A/160 6 / 0.22 3.0 — 80VA 350 7.2/30/60
JDZ10-10A/160 10 / 0.22 3.0 — 80VA 350 12/42/75
Selection Note: One transformer is supplied with one selected accuracy class and corresponding rated output combination. The 0.1kV output is normally used for metering, voltage indication and monitoring. The 0.1/0.1kV version is used when two separated secondary circuits are required. The 0.22kV output is suitable for auxiliary voltage requirements in cabinet designs.

Installation & Wiring

Installation Diagram

Installation Diagram

The JDZ10-3,6,10A (RZL10) indoor epoxy cast-resin voltage transformer is designed for secure mounting on a flat base using the main mounting holes spaced at 300 ±2mm. Ensure proper alignment with the overall base dimensions (330 ±2mm length and 160 ±1mm width) and maintain adequate clearance around the unit for ventilation and safety during installation.

Wiring Diagram

Wiring Diagram

Primary terminals are marked A and B as shown in the wiring diagram. Secondary terminals may be labeled a, b for single-secondary configurations or 1a, 1b, 2a, 2b for dual-secondary arrangements. For units with a 0.22kV auxiliary secondary output, verify the load requirement and rated output prior to production. Always confirm terminal polarity, grounding connection (using the M8 grounding bolt), and cabinet clearance before commissioning.

Terminal polarity, grounding and cabinet clearance must be checked before commissioning.

Selection & FAQs

Selection Guide

  • Use this model for phase-to-phase measurement. Primary terminals A and B connect across two phases; do not substitute it for a phase-to-earth JDZX model.
  • Select one secondary architecture. Choose a single 100V output, two independent 100V outputs, or the 220V class 3 auxiliary version.
  • Match accuracy and burden. Single-output options are 0.2/20VA, 0.5/50VA, 1/100VA or 3/200VA; dual outputs are 10/10VA.
  • Do not use 350VA/400VA as accuracy outputs. These are maximum thermal references; accurate burden is limited to the selected row.
  • Confirm insulation, temperature and layout. Select the correct 3.6/25/40, 7.2/30/60 or 12/42/75kV version, and resolve −5°C versus claimed −25°C service before ordering.

Frequently Asked Questions

Q1: What is the maximum rated output for this voltage transformer?

The maximum output is 400VA across all model variants. It provides rated outputs from 20VA to 200VA depending on the chosen accuracy class. Contact us for specific load requirements.

Q2: Can this epoxy cast-resin transformer be installed outdoors?

No, it is strictly designed for indoor installation. The environment must be non-corrosive, non-explosive, and free from severe vibration. Verify site conditions before ordering.

Q3: Which accuracy class is suitable for standard monitoring applications?

The 1.0 or 3.0 accuracy class is ideal for general monitoring. The 0.2 and 0.5 classes are reserved for precision metering. Specify your exact needs during procurement.

Q4: Do these voltage transformers comply with IEC standards?

Yes, the JDZ10 series fully complies with IEC 61869 standards. It is designed for medium-voltage switchgear applications up to 12kV. Request specific type test reports for your project.

Q5: Are factory acceptance tests provided before shipment?

Yes, standard routine tests are conducted prior to dispatch. Specific type tests or third-party inspections are subject to confirmation. Contact our sales team for detailed testing protocols.

Q6: How is the JDZ10-10A model typically applied in switchgear?

It serves as a 10kV indoor epoxy cast-resin voltage transformer for metering and auxiliary power. It features a 12/42/75kV rated insulation level. Confirm switchgear dimensions with our engineers.

Q7: When should we request factory derating for altitude?

Derating is required for installations exceeding 1000m above sea level. The standard operating altitude is up to 1000m with ambient temperatures between -5°C and +40°C. Please consult us for high-altitude projects.

Inquiry for JDZ10-3/6/10A RZL10 indoor epoxy cast-resin Voltage Transformer:

Send your project requirements. Our team will reply with technical details and quotation.

  • Fast response
  • Technical support
  • OEM / ODM