Transformer Arus Dalam Bangunan RCT untuk Pengukuran Arus yang Tepat
Description The RCT Indoor Current Transformer is designed for use in electrical systems with a rated frequency of 50Hz or 60Hz and a rated voltage of 0.66kV or below. It is primarily used for electric energy measurement, current measurement, and relay protection applications. This product is ideal for small and medium-scale electrical systems, offering accurate performance […]
- Penerangan
- Penamaan Jenis bagi Pemboleh Ubah Arus Dalaman RCT
- Pembinaan Pemboleh Ubah Arus Dalaman RCT
- Data Teknikal Pemboleh Ubah Arus Dalaman RCT
- Keadaan Pengendalian bagi Pemboleh Ubah Arus Dalaman RCT
- Lakaran dan Dimensi Pemboleh Ubah Arus Dalaman RCT
- Soalan Lazim (FAQ) mengenai Pemboleh Ubah Arus Dalaman RCT
Penerangan
Penamaan Jenis bagi Pemboleh Ubah Arus Dalaman RCT

Pembinaan Pemboleh Ubah Arus Dalaman RCT
Pemboleh ubah arus ini mempunyai teras besi jenis gelung, yang direka untuk meningkatkan sifat magnetiknya demi prestasi cekap. Lilitan sekunder dililit secara seragam di sekeliling teras, memastikan pengukuran yang konsisten dan tepat.
Produk ini dilengkapi dengan plat pemasangan di bahagian bawah, memberikan pemasangan yang selamat. Tambahan pula, terdapat lubang dalam rekabentuknya yang membolehkan palang bas (busbar) melalui nip, memudahkan integrasi lancar ke dalam sistem elektrik.
Ciri-ciri Utama:
- Teras Besi Jenis Gelung:
Teras besi berbentuk gelung ini mengoptimumkan fluks magnetik dan memastikan transformasi arus yang berkesan. Konfigurasi ini membantu mengekalkan prestasi konsisten dalam tempoh masa panjang. - Lilitan Sekunder Seragam:
Lilitan sekunder dililit secara seragam di sekeliling teras, memastikan output yang tepat dan boleh dipercayai. Konsistensi ini amat penting untuk ketepatan dalam pengukuran arus dan sistem perlindungan. - Plat Pemasangan untuk Pemasangan Selamat:
Pemboleh ubah ini termasuk plat pemasangan di bahagian bawah untuk pemasangan mudah dan selamat, memastikan operasi stabil dalam sistem. - Akses Palang Bas (Busbar):
Rekabentuknya termasuk lubang untuk palang bas melalui nip, memudahkan sambungan terus ke sistem elektrik tanpa perlu pengubahsuaian rumit.
Data Teknikal Pemboleh Ubah Arus Dalaman RCT
| Jenis | Nisbah transformasi penarafan (A) |
Konfigurasi kumpulan |
Bilangan lilitan terus |
Kelas ketepatan dan output penarafan (VA) COS φ = 8 |
Aras penebatan penarafan (kV) |
||||
| Keratan (mm) |
Belian | ||||||||
| 10 | 0.5 | 1 | 0.5/3 | ||||||
| ϕ 35 | 15/5 | 10 | 5 | 10 | |||||
| 20/5 | 5 | ||||||||
| 30/5 | 5 | ||||||||
| 40/5 | 3 | ||||||||
| 50/5 | 2 | ||||||||
| 75/5 | 2 | ||||||||
| 100/5 | 1 | ||||||||
| 150/5 | 30 * 10 | 1 | 1 | ||||||
| 200/5 | 30 * 10 | 1 | 1 | ||||||
| 300/5 | 30 * 10 | 1 | 1 | ||||||
| ϕ 58 | 400/5 | 50 * 10 | 1 | 1 | 10 | 15 | |||
| 500/5 | 50 * 10 | 1 | 1 | ||||||
| 600/5 | 50 * 10 | 1 | 1 | ||||||
| 800/5 | 50 * 10 | 1 | 1 | ||||||
| ϕ 90 | 1000/5 | 80 * 10 | 60 * 10 | 1 | 1-2 | 1 | 15 | 25 | |
| 1200/5 | 80 * 10 | 60 * 10 | 1 | 1-2 | 1 | ||||
| 1500/5 | 80 * 10 | 60 * 10 | 1 | 1-2 | 1 | ||||
| ϕ 110 | 1500/5 | 100 * 10 | 80 * 10 | 1 | 1-2 | 1 | |||
| 2000/5 | 100 * 10 | 80 * 10 | 1 | 1-2 | 1 | ||||
| 2500/5 | 100 * 10 | 80 * 10 | 1 | 1-2 | 1 | ||||
| 3000/5 | 100 * 10 | 80 * 10 | 1 | 1-2 | 1 | ||||
| 4000/5 | 100 * 10 | 80 * 10 | 1 | 1-2 | 1 | ||||
| 5000/5 | 100 * 10 | 80 * 10 | 1 | 1-2 | 1 | ||||
Keadaan Pengendalian bagi Pemboleh Ubah Arus Dalaman RCT
1. Tempat kerja: Dalaman
2. Suhu persekitaran: -5℃~40℃
3. Kelembapan: <80%
4. Ketinggian: <1000m
5. Keadaan atmosfera: tiada pencemaran serius
Lakaran dan Dimensi Pemboleh Ubah Arus Dalaman RCT

| Jenis | d | A | B | D | G | H | L |
|---|---|---|---|---|---|---|---|
| RCT | -35 | 95 | 80 | 78 | 45 | 90 | 54 |
| RCT | -58 | 110 | 88 | 100 | 45 | 113 | 56 |
| RCT | -90 | 110 | 88 | 135 | 38 | 147 | 40 |
| RCT | -110 | 110 | 88 | 163 | 38 | 177 | 40 |
Soalan Lazim (FAQ) mengenai Pemboleh Ubah Arus Dalaman RCT
- Apakah aplikasi utama Pemboleh Ubah Arus Dalaman RCT? RCT digunakan untuk pengukuran arus tepat, pengukuran tenaga, dan perlindungan geganti dalam sistem elektrik voltan rendah.
- Bolehkah pemboleh ubah RCT digunakan di luar bangunan? Tidak, pemboleh ubah RCT direka khusus untuk kegunaan dalaman sahaja.
- Berapakah voltan penarafan maksimum bagi pemboleh ubah RCT? Pemboleh ubah RCT direka untuk digunakan dalam sistem dengan voltan penarafan 0.66kV atau kurang.
- Apakah ciri utama reka bentuk pemboleh ubah RCT? RCT mempunyai teras besi jenis gelung yang tahan lasak dan lilitan sekunder seragam untuk transformasi dan pengukuran arus yang tepat.
- Adakah pemboleh ubah RCT boleh disesuaikan? Ya, pemboleh ubah RCT boleh disesuaikan dengan nisbah arus dan kelas ketepatan berbeza mengikut keperluan operasi tertentu.